Ambulatory Monitors, Telemetry and Stress Tests
Match the monitor to how often symptoms occur, hook it up on well-prepared skin, and teach the patient. For a stress test: Mason-Likar placement, baseline vitals, continuous 12-lead, blood pressure about every 2 minutes, stop on absolute criteria, and a target of 85% of 220 minus age.
Ambulatory devices
| device | how it records | typical wear | patient teaching |
|---|---|---|---|
| Holter | Every beat, continuously, wired gel electrodes | 24-48 hours (some longer) | Shower before the hookup; keep a diary; avoid magnets, metal detectors, electric blankets, high-voltage areas |
| Patch monitor | 1-2 leads from built-in electrodes, no wires | Up to about 14 days | Press the button to mark symptoms; many can get wet |
| External loop recorder | Rolling memory saved before, during and after a button press or auto-trigger | Weeks, up to about 30 days | Press the button with symptoms |
| Symptom (post-event) recorder | Only after the patient applies it during symptoms | Carried for weeks | Place it on the chest when symptoms start |
| Mobile cardiac telemetry | Continuous; sends data to a reading centre | Days to weeks | Follow the centre's steps |
| Implantable loop recorder | Under the skin, placed by a provider | Years |
Electrodes and leads (ISHNE-HRS): 1 lead needs 2 electrodes, 2 leads need 3, 3 leads need 5-7, a 12-lead Holter needs 10 (Mason-Likar sites).
A standard Holter does not alarm or analyse in real time; the provider reads it after the recording. A blank diary is filled from recall and marked as recalled, never invented.
Preview only. The full sheet also covers: Choosing the test; 5-electrode telemetry hookup (AHA colours); Exercise stress test: setup and monitoring; Contraindications (screen and report; the provider decides); When to stop (ACC/AHA list); Target heart rate formulas.
Sources
- Steinberg JS, Varma N, et al. 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry. Ann Noninvasive Electrocardiol. 2017;22(3):e12447 (PMC6931745) · International Society for Holter and Noninvasive Electrocardiology / Heart Rhythm Society (via PubMed Central)
- Cascino T. Electrocardiography (ECG) (Merck Manual Professional Version) · Merck & Co. (Merck Manual Professional Version)
- Holter heart monitor (24h) (MedlinePlus Medical Encyclopedia; fact-checking only) · MedlinePlus, U.S. National Library of Medicine (A.D.A.M.)
- Cardiac event monitors (Medical Encyclopedia, fact-checking only) · MedlinePlus, National Library of Medicine (A.D.A.M.)
- Electrocardiogram (EKG) test (MedlinePlus Medical Tests) · MedlinePlus, U.S. National Library of Medicine
- Nursing Advanced Skills (Open RN, WisTech Open, CC BY 4.0), 7.6 Checklist: Initiate Telemetry (5-electrode placement with AHA colours, citing Drew et al. 2004 AHA practice standards) · WisTech Open / Chippewa Valley Technical College (Pressbooks)
- Drew BJ, Harris P, Zègre-Hemsey JK, et al. Insights into the problem of alarm fatigue with physiologic monitor devices: a comprehensive observational study of consecutive intensive care unit patients. PLoS One. 2014;9(10):e110274 (PMC4206416) · PLoS ONE (via PubMed Central)
- Zègre-Hemsey JK, Garvey JL, Carey MG. Cardiac Monitoring in the Emergency Department. Crit Care Nurs Clin North Am. 2016;28(3):331-345 (author manuscript, PMC5630152) · Critical Care Nursing Clinics of North America (via PubMed Central)
- Pelter MM, Kozik TM, Loranger DL, Carey MG. A research method for detecting transient myocardial ischemia in patients with suspected acute coronary syndrome using continuous ST-segment analysis. J Vis Exp. 2012;(70):e50124 (PMC3577868) · Journal of Visualized Experiments (via PubMed Central)
- Carluccio C, Bressan F, Pizzolato M, et al. Exercise Stress Testing in Clinical Cardiology: A Practical Guide to Performance and Interpretation. J Clin Med. 2026;15(4):1656 (PMC12942606, CC BY; Mason-Likar placement, skin preparation, blood pressure schedule, Borg scales, room and crash cart, cool-down, Table 2 termination criteria adapted from the AHA 2013 Exercise Standards); read via NCBI E-utilities full text · MDPI Journal of Clinical Medicine (via PubMed Central)
- Exercise stress test (MedlinePlus Medical Encyclopedia; fact-checking only) · MedlinePlus, U.S. National Library of Medicine (A.D.A.M.)
- Nuclear stress test (Medical Encyclopedia, fact-checking only) · MedlinePlus, National Library of Medicine (A.D.A.M.)
- Cardiac Stress Testing (Merck Manual Professional Version; contraindications list cites Fletcher GF et al., AHA Exercise Standards for Testing and Training, Circulation 2013) · Merck & Co. (Merck Manual Professional Version)
- Kabbadj K, Taiek N, et al. Cardiopulmonary Exercise Testing: Methodology, Interpretation, and Role in Exercise Prescription for Cardiac Rehabilitation. US Cardiol. 2024;18:e22 (PMC11770537) · US Cardiology Review (via PubMed Central)
- Myers J, Forman DE, Balady GJ, et al. Supervision of Exercise Testing by Nonphysicians: A Scientific Statement From the American Heart Association. Circulation. 2014;130(12):1014-1027 (author manuscript PMC7304043; supervision levels, patients needing personal physician supervision, complication rates, BLS credentialing, emergency alarm) · American Heart Association (via PubMed Central)
- Jowett N, et al. Modified electrode placement must be recorded when performing 12-lead electrocardiograms. Postgrad Med J. 2005;81:122-125 (abstract read) · PubMed Central
- Morales-Arteaga JL, Meghdadi A, et al. Alternative Lead ECG Placements. Ann Noninvasive Electrocardiol. 2026;31(3):e70176 (CC BY 4.0) · Wiley, Annals of Noninvasive Electrocardiology (via PubMed Central)
- Pilot study protocol, Trials 2013;14:91 (PMC3653687), Table 6: American College of Cardiology/American Heart Association indications for terminating exercise testing (absolute and relative); read via NCBI E-utilities full text · BioMed Central Trials (via PubMed Central)
- Czechowska B, et al. Reasons for Termination of Treadmill and Cycle Ergometer Exercise Tests in Patients After Myocardial Infarction. J Clin Med. 2026 (PMC13412373; cycle ergometer preferred for balance disorders or fall risk); read via NCBI E-utilities full text · MDPI Journal of Clinical Medicine (via PubMed Central)
- LIFE Study Manual of Procedures, Chapter 12: Electrocardiogram v2.0 (2010) · National Institute on Aging, Aging Research Biobank
- Anatomy and Physiology 2e, 19.4 Cardiac Physiology (cardiac output = HR x SV, normal resting adult HR 60-100 bpm, bradycardia and tachycardia, maximum HR estimated as 220 minus age, autonomic control of HR; OpenStax, CC BY 4.0; fact-checking only) · OpenStax, Rice University
- Tanaka H, Monahan KD, Seals DR. Age-predicted maximal heart rate revisited. J Am Coll Cardiol. 2001;37(1):153-156 (220 - age is commonly used as a clinical guide during exercise testing; regression 208 - 0.7 x age; 220 - age underestimates HRmax in older adults) (PubMed abstract) · Journal of the American College of Cardiology via PubMed
- Rehab Pearls: Karvonen formula for calculating individualized target heart rate (heart rate reserve = max HR - resting HR; target = intensity x HRR + resting HR; worked example) · UCLA Health Rehabilitation Services
- Ignaszewski M, Lau B, Wong S, Isserow S. The science of exercise prescription: Martti Karvonen and his contributions. BCMJ. 2017;59(1):38-41 (heart rate reserve = peak minus resting heart rate; intensity bands as % of HRR) · British Columbia Medical Journal
- Pinkstaff S, Peberdy MA, Kontos MC, Finucane S, Arena R. Quantifying exertion level during exercise stress testing using percentage of age-predicted maximal heart rate, rate pressure product, and perceived exertion. Mayo Clin Proc. 2010;85(12):1095-1100 (attainment of at least 85% of age-predicted maximal heart rate, 220 - age, as the conventional exertion criterion; its limits) · Mayo Clinic Proceedings via PubMed Central
- Guide for Aviation Medical Examiners: Graded Exercise Stress Test Requirements, last updated May 29, 2024 (percent of predicted maximal heart rate; studies below 85% of maximum predicted heart rate; beta blockers, diltiazem, verapamil and digitalis held only with the treating physician's consent in order to obtain maximum heart rate) · Federal Aviation Administration, U.S. Department of Transportation
Test yourself: free EKG practice questions on EKG Acquisition
Free practice questions on this topic
- Free EKG practice test, question 9A patient arrives for his scheduled resting 12-lead and hands the technician a printed tracing from his smartwatch, saying, "I already did my EKG at…
- Free EKG practice test, question 10A technician finishes a tracing with the chest leads mirrored on the right side for a patient with dextrocardia. What must be added to the tracing?
- Free EKG practice test, question 11Reviewing a fresh tracing, the technician finds a nearly isoelectric lead II, while lead III is unchanged from the patient's prior tracing. Which…
More EKG Acquisition
- Free EKG Acquisition questions
- EKG Acquisition terms
- Electrode Placement: 12-Lead, Monitoring and Special Views
- Artifacts, Faulty Electrodes and Lead Reversals
Medlo is an independent app. It is not affiliated with, endorsed by, or sponsored by the National Healthcareer Association (NHA). NHA and Certified EKG Technician (CET) are trademarks of the National Healthcareer Association, used here only to name the exam.