Medlo
Get the app

Free NHA EKG (CET) Practice Test (2026)

The NHA EKG technician (CET) exam has 120 questions (100 scored) in 2 hours, and you pass with a scaled score of 390 on a 200–500 scale. EKG Acquisition is 44 of the 100 scored questions (44%); each of the other 2 domains is 24 to 32. NHA reports 23,429 exams given in 2025, with a pass rate of 70.45%. This free test has 25 questions weighted the same way; the free full-length test has 100 more, none of them repeated here. Then try the free EKG rhythm strip quiz.

Tap an answer to check it, see your score by domain and read why every wrong option is wrong. No sign-up.

Want more? Take the free 100-question full-length EKG practice test, practice test 2 or practice test 3.

25 NHA EKG (CET) practice questions with answer explanations

25 questions. Tap an answer to check it, or open the explanation under each one.

Question 1 · Safety, Compliance, and Coordinated Patient Care

A cardiology practice employs an EKG technician. During a routine 12-lead in the office, she forgets to raise the stretcher rail and the patient falls. Under respondeat superior, which party can also be held responsible for her negligence?

  1. The patient's health insurer
  2. The practice that employs her
  3. NHA, which certified her
  4. The company that built the stretcher
Show answer and explanation

Correct answer: B. The practice that employs her

Under respondeat superior, an employer with the right to control an employee's work is answerable for that employee's negligence on the job (Thornton 2010).

Why the other options are wrong

  • A. The patient's health insurer: An insurer does not employ or control the technician.
  • C. NHA, which certified her: A certifying body does not employ her or direct her work.
  • D. The company that built the stretcher: The fall came from the technician's care, not a product defect.

Question 2 · Safety, Compliance, and Coordinated Patient Care

Seated quietly before her stress echo, a woman's properly taken pressure is 124/76 mm Hg. Using the 2025 AHA/ACC categories, how is this value labeled?

  1. Hypertension stage 1
  2. Normal
  3. Elevated
  4. Hypertension stage 2
Show answer and explanation

Correct answer: C. Elevated

The 2025 table puts a systolic of 120-129 together with a diastolic under 80 in the elevated category.

Why the other options are wrong

  • A. Hypertension stage 1: Stage 1 needs a systolic of 130 or more or a diastolic of 80 or more.
  • B. Normal: Normal requires a systolic below 120 mm Hg.
  • D. Hypertension stage 2: A systolic of 124 is far below the 140 that begins stage 2.

Question 3 · Safety, Compliance, and Coordinated Patient Care

The cardiology clinic gives every Holter patient a printed instruction sheet. What is the best way to use it?

  1. Use it instead of spoken teaching to save time
  2. Give it only to patients who ask for something in writing
  3. Hand it over at checkout for the patient to read later
  4. Go over it with the patient and mark the key points
Show answer and explanation

Correct answer: D. Go over it with the patient and mark the key points

A handout is part of the teaching, not a substitute: go through it together, circle or highlight what matters most, and check understanding with teach-back.

Why the other options are wrong

  • A. Use it instead of spoken teaching to save time: A handout supports, and cannot stand in for, spoken teaching.
  • B. Give it only to patients who ask for something in writing: Planned education should not depend on the patient asking.
  • C. Hand it over at checkout for the patient to read later: Patients may not read material they are simply handed.

Question 4 · Safety, Compliance, and Coordinated Patient Care

Before any electrodes are placed, a 58-year-old outpatient slumps off the EKG table. He does not respond to tapping and shouting and is making only occasional gasping breaths. A coworker is at the door, and an AED hangs in the hallway. What should the technician do?

  1. Roll him into the recovery position and keep watching his breathing
  2. Send the coworker to call 911 and fetch the AED; start compressions
  3. Take his blood pressure now and reassess him in two minutes
  4. Finish placing all ten electrodes so the tracing documents his rhythm first
Show answer and explanation

Correct answer: B. Send the coworker to call 911 and fetch the AED; start compressions

Collapse, no response and absent or only gasping breathing are signs of cardiac arrest. The rescuer has someone activate emergency help and bring the AED, and starts CPR right away.

Why the other options are wrong

  • A. Roll him into the recovery position and keep watching his breathing: Side-lying recovery suits only someone with normal breathing, and gasping does not count.
  • C. Take his blood pressure now and reassess him in two minutes: Measuring vital signs delays emergency care for a patient in arrest.
  • D. Finish placing all ten electrodes so the tracing documents his rhythm first: A diagnostic tracing is not needed to start BLS and only delays compressions.

Question 5 · Safety, Compliance, and Coordinated Patient Care

At an off-site health screening event with no sink, a technician removes gloves after a patient's nosebleed and finds blood on one hand. What does OSHA allow?

  1. No cleaning until the event is over
  2. Antiseptic cleanser now, washing later
  3. A dry paper towel, then back to work
  4. New gloves pulled on over the soiled hand
Show answer and explanation

Correct answer: B. Antiseptic cleanser now, washing later

When a sink is not feasible, OSHA 1910.1030(d)(2)(iv) has the employer supply antiseptic towelettes or an antiseptic cleanser with clean cloth or paper towels. A proper wash with soap and running water still follows at the first feasible chance.

Why the other options are wrong

  • A. No cleaning until the event is over: Hands are cleaned immediately or as soon as feasible, not hours later.
  • C. A dry paper towel, then back to work: Drying does not remove or inactivate the blood.
  • D. New gloves pulled on over the soiled hand: Gloves over contaminated skin trap the blood and are not hand hygiene.

Sources

Question 6 · Safety, Compliance, and Coordinated Patient Care

After two-identifier verification, a patient says, "I go by Alex and use they/them." The legal first name on the order is different. Later the technician calls the nurse about the tracing. How should the technician refer to the patient?

  1. As Alex, using they/them, with the identifiers needed to match the record
  2. By the legal first name only, since that is in the chart
  3. As he or she, based on the sex listed in the chart
  4. By last name only, to avoid the question
Show answer and explanation

Correct answer: A. As Alex, using they/them, with the identifiers needed to match the record

Use the name and pronouns the patient gives, because gender cannot be assumed from appearance or the chart; legal identifiers are still used to match the record.

Why the other options are wrong

  • B. By the legal first name only, since that is in the chart: The legal name serves identification; addressing the patient uses the name they gave.
  • C. As he or she, based on the sex listed in the chart: Gender cannot be read from the chart or from appearance.
  • D. By last name only, to avoid the question: Avoiding the name the patient asked for is not respectful care.

Question 7 · Safety, Compliance, and Coordinated Patient Care

An EKG machine with dried blood on its keyboard is being boxed up to go out for repair. What does OSHA require?

  1. Wipe only the screen and ship it
  2. Decontaminate it as needed before shipping
  3. Send it unchanged and let the repair shop clean it
  4. Remove the blood with a dry paper towel only
Show answer and explanation

Correct answer: B. Decontaminate it as needed before shipping

OSHA: equipment that may be contaminated with blood is examined before servicing or shipping and decontaminated as necessary; parts that cannot be decontaminated are identified with a biohazard label.

Why the other options are wrong

  • A. Wipe only the screen and ship it: The contaminated keyboard is the part that needs attention.
  • C. Send it unchanged and let the repair shop clean it: The sender must examine and decontaminate before shipping.
  • D. Remove the blood with a dry paper towel only: A dry towel does not decontaminate.

Sources

Question 8 · Safety, Compliance, and Coordinated Patient Care

A 12-lead is ordered for a patient in a negative-pressure airborne isolation room. A nurse suggests leaving the door open during the test so the EKG cart's power cord can reach a hallway outlet. What is the correct response?

  1. Keep it closed except to enter and leave
  2. Leave it open, since the test is brief
  3. Leave it open while the tracing records
  4. Leave it open if the patient wears a mask
Show answer and explanation

Correct answer: A. Keep it closed except to enter and leave

CDC: the AIIR door is opened only for someone to go in or come out, so the negative pressure keeps pulling air into the room rather than letting it escape to the hallway.

Why the other options are wrong

  • B. Leave it open, since the test is brief: A short test does not justify breaking the closed-door rule.
  • C. Leave it open while the tracing records: Recording time is exactly when the door must stay shut.
  • D. Leave it open if the patient wears a mask: The door rule does not depend on masking, and the patient may unmask inside the AIIR.

Question 9 · EKG Acquisition

A patient arrives for his scheduled resting 12-lead and hands the technician a printed tracing from his smartwatch, saying, "I already did my EKG at home." What should the technician do?

  1. Mount the smartwatch printout in the chart instead of a 12-lead
  2. Throw the printout away, since home devices are not allowed
  3. Compare the printout with his last 12-lead and tell him the result
  4. Record the ordered 12-lead and give the printout to the provider
Show answer and explanation

Correct answer: D. Record the ordered 12-lead and give the printout to the provider

Consumer smartwatches can record a single-lead ECG that can be saved, printed or sent, and their clinical role is still under study. They do not replace the ordered 12-lead; the technician performs the ordered test and passes the printout to the provider.

Why the other options are wrong

  • A. Mount the smartwatch printout in the chart instead of a 12-lead: A single-lead consumer tracing does not replace an ordered 12-lead.
  • B. Throw the printout away, since home devices are not allowed: The printout may interest the provider; the technician hands it on instead of discarding it.
  • C. Compare the printout with his last 12-lead and tell him the result: Interpreting tracings and giving results is the provider's role.

Question 10 · EKG Acquisition

A technician finishes a tracing with the chest leads mirrored on the right side for a patient with dextrocardia. What must be added to the tracing?

  1. Nothing, because the machine detects the new placement
  2. A label showing the chest leads as V1R to V6R
  3. A note telling the reader to disregard the chest leads
  4. A note that the gain setting was doubled
Show answer and explanation

Correct answer: B. A label showing the chest leads as V1R to V6R

Right-sided acquisition is documented clearly on the tracing (for example, labelled V1R to V6R) so the reader does not mistake it for a standard 12-lead and misinterpret it.

Why the other options are wrong

  • A. Nothing, because the machine detects the new placement: The machine prints whatever lead names it is set to; it does not know the electrodes were moved.
  • C. A note telling the reader to disregard the chest leads: The mirrored chest leads are the reason for the test and must be read, with a clear label.
  • D. A note that the gain setting was doubled: Nothing in the scenario changed the gain; the placement is what must be documented.

10 down. Medlo has 637 more EKG (CET) questions, each answer explained. Get Medlo

Question 11 · EKG Acquisition

Reviewing a fresh tracing, the technician finds a nearly isoelectric lead II, while lead III is unchanged from the patient's prior tracing. Which pair of electrodes was most likely exchanged?

  1. Right arm and right leg
  2. V5 and V6 chest electrodes
  3. Left arm and right leg
  4. Right arm and left arm
Show answer and explanation

Correct answer: A. Right arm and right leg

With the right arm and right leg (neutral) electrodes reversed, lead II records a near-flat line and lead III is unchanged. Fix the connections and record again.

Why the other options are wrong

  • B. V5 and V6 chest electrodes: A chest-lead swap does not affect the limb leads.
  • C. Left arm and right leg: Left arm and right leg reversal flattens lead III instead.
  • D. Right arm and left arm: Arm reversal inverts lead I; it does not flatten lead II.

Question 12 · EKG Acquisition

A patient wearing an auto-triggered external loop recorder slept through a brief run of fast heartbeats. Can the device have captured it?

  1. No, a recording is saved when the patient presses the button
  2. No, loop recorders are switched off during sleep
  3. Yes, provided the patient wrote it in the diary
  4. Yes, its auto-trigger can save rhythms the patient did not notice
Show answer and explanation

Correct answer: D. Yes, its auto-trigger can save rhythms the patient did not notice

Many loop recorders have an auto-trigger that saves the ECG around an abnormal rhythm on its own, so they can document both symptomatic and asymptomatic arrhythmias.

Why the other options are wrong

  • A. No, a recording is saved when the patient presses the button: Auto-triggered devices do not depend only on the patient's button.
  • B. No, loop recorders are switched off during sleep: Loop recorders are worn continuously, including during sleep.
  • C. Yes, provided the patient wrote it in the diary: The diary helps correlation but does not control what the device saves.

Sources

Question 13 · EKG Acquisition

A patient shows the technician a single-lead tracing he recorded by touching electrodes built into his smartphone case. ISHNE-HRS groups this recorder with which device type?

  1. Mason-Likar 12-lead monitors
  2. Standard multichannel Holter recorders
  3. Patient-activated post-event recorders
  4. Implantable loop recorders
Show answer and explanation

Correct answer: C. Patient-activated post-event recorders

ISHNE-HRS lists smartphone-based ECG systems, which record a single lead from electrodes in the phone case, under intermittent patient-activated post-event recorders.

Why the other options are wrong

  • A. Mason-Likar 12-lead monitors: Mason-Likar uses 10 electrodes on the torso.
  • B. Standard multichannel Holter recorders: A Holter records continuously through wired electrodes.
  • D. Implantable loop recorders: Implantable recorders sit under the skin.

Question 14 · EKG Acquisition

On night shift, the only monitor technician at the central telemetry station is asked to help move a patient on another unit for a few minutes. What should happen before the technician leaves the station?

  1. Pause the arrhythmia analysis until the technician returns
  2. Hand off the station to a designated backup per protocol
  3. Turn the alarm volume up so staff nearby can hear it
  4. Ask the patients to press their call lights if they feel unwell
Show answer and explanation

Correct answer: B. Hand off the station to a designated backup per protocol

An unattended central station is a known failure point in telemetry monitoring; a formal backup coverage protocol ensures someone is watching while the technician is away.

Why the other options are wrong

  • A. Pause the arrhythmia analysis until the technician returns: Pausing analysis leaves patients unmonitored.
  • C. Turn the alarm volume up so staff nearby can hear it: A louder alarm does not ensure anyone is responsible for responding.
  • D. Ask the patients to press their call lights if they feel unwell: Patients may not feel a dangerous rhythm, so monitoring cannot rely on them.

Question 15 · EKG Acquisition

A tense patient's tracing shows small, irregular deflections of varying speed riding on the waveforms. Which artifact is this?

  1. 60-cycle interference
  2. Wandering baseline
  3. Somatic tremor
  4. Lead wire reversal
Show answer and explanation

Correct answer: C. Somatic tremor

Somatic tremor shows as small, irregular oscillations of changing speed laid over the complexes. It is caused by the patient's own involuntary muscle activity, typically when the patient is tense, cold or uncomfortable.

Why the other options are wrong

  • A. 60-cycle interference: 60-cycle interference is perfectly regular, not irregular.
  • B. Wandering baseline: A wandering baseline is a slow up-and-down drift.
  • D. Lead wire reversal: A wire reversal changes the direction of waveforms, not the texture of the baseline.

Question 16 · EKG Acquisition

A patient is starting three weeks of mobile cardiac telemetry with a wire-and-electrode system. Which practical demand of this device type does ISHNE-HRS describe?

  1. The recorder must be emptied by hand every night
  2. The device records during sleep and pauses during the day
  3. The electrodes need to be changed every day
  4. The patient must call in every symptom by phone
Show answer and explanation

Correct answer: C. The electrodes need to be changed every day

ISHNE-HRS notes that electrode-wire MCT systems require daily electrode changes, which lowers patient acceptance for long-term monitoring.

Why the other options are wrong

  • A. The recorder must be emptied by hand every night: MCT transmits data to the reading center on its own.
  • B. The device records during sleep and pauses during the day: MCT is worn and records continuously, day and night, not just during sleep.
  • D. The patient must call in every symptom by phone: MCT sends data without the patient taking part in transmission.

Question 17 · EKG Acquisition

Why is putting the limb electrodes on the torso for a routine resting 12-lead not a harmless shortcut in adults?

  1. It makes the calibration pulse print too small to read
  2. It disconnects the chest leads
  3. It doubles the recording time
  4. It can create or hide abnormal-looking patterns
Show answer and explanation

Correct answer: D. It can create or hide abnormal-looking patterns

In a 100-patient comparison, torso limb electrodes produced important ECG abnormalities in 36% of patients whose standard tracings were normal and made some infarct patterns appear or disappear; any modification must be noted on the tracing.

Why the other options are wrong

  • A. It makes the calibration pulse print too small to read: Calibration is a machine setting, not affected by electrode sites.
  • B. It disconnects the chest leads: Chest leads are unaffected in their connection.
  • C. It doubles the recording time: Placement does not change recording time.

Question 18 · EKG Acquisition

For a patient on continuous bedside monitoring, where should the monitoring electrodes go to reduce muscle noise?

  1. On bony chest areas
  2. Over the biceps and thighs
  3. Over the shoulder muscles
  4. Over the abdominal muscles
Show answer and explanation

Correct answer: A. On bony chest areas

Monitoring electrodes stay on for a long time, so they go on cleaned skin over bony prominences rather than muscle, where they are more stable and pick up less muscle noise.

Why the other options are wrong

  • B. Over the biceps and thighs: Large limb muscles add muscle noise.
  • C. Over the shoulder muscles: Shoulder muscles add muscle noise with arm movement.
  • D. Over the abdominal muscles: Abdominal muscles move with breathing and add noise.

Question 19 · EKG Acquisition

Which patient action just before a resting EKG may give false results?

  1. Removing a necklace
  2. Taking off shoes
  3. Drinking cold water
  4. Using the restroom first
Show answer and explanation

Correct answer: C. Drinking cold water

Patients should not exercise or drink cold water immediately before an EKG, because these can cause false results.

Why the other options are wrong

  • A. Removing a necklace: Removing jewelry from the chest helps electrode placement.
  • B. Taking off shoes: Shoes do not affect the tracing.
  • D. Using the restroom first: Using the restroom helps the patient lie still.

Sources

Question 20 · EKG Analysis and Interpretation

How does the technician measure the QRS duration?

  1. From the first deflection of the QRS to its end
  2. From the start of the QRS to the peak of the T wave
  3. From the peak of the R wave to the peak of the S wave
  4. From P-wave end to QRS end
Show answer and explanation

Correct answer: A. From the first deflection of the QRS to its end

QRS duration is measured from the beginning to the end of the QRS complex.

Why the other options are wrong

  • B. From the start of the QRS to the peak of the T wave: Measuring to the T peak adds the ST segment and part of the T wave.
  • C. From the peak of the R wave to the peak of the S wave: Peak-to-peak leaves out the start and end of the complex.
  • D. From P-wave end to QRS end: Starting at the P-wave end adds the PR segment.

Sources

Question 21 · EKG Analysis and Interpretation

After the code team takes over a patient in VF, what can the technician still usefully do?

  1. Leave, since the team has arrived
  2. Explain the rhythm diagnosis to the family
  3. Help as directed, such as compressions
  4. Decide when to give the next shock
Show answer and explanation

Correct answer: C. Help as directed, such as compressions

When two or more rescuers are present, compressors switch about every 2 minutes to prevent fatigue; a trained technician helps as directed by the team leader.

Why the other options are wrong

  • A. Leave, since the team has arrived: Trained help is still needed, for example to rotate compressors.
  • B. Explain the rhythm diagnosis to the family: Explaining a diagnosis is the provider's role.
  • D. Decide when to give the next shock: Shock decisions belong to the team leader or the device prompts.

Question 22 · EKG Analysis and Interpretation

Serial tracings are taken during an untreated ST-elevation MI. In which order do the classic changes usually appear?

  1. T inversion, then hyperacute T waves, then ST elevation
  2. Q waves, then ST elevation, then T inversion
  3. ST elevation, then hyperacute T waves, then Q waves
  4. Hyperacute T waves, then ST elevation, then Q waves
Show answer and explanation

Correct answer: D. Hyperacute T waves, then ST elevation, then Q waves

Hyperacute T waves come first, ST elevation follows within hours, and pathological Q waves develop over hours as muscle dies; later the ST segment settles and the T wave inverts.

Why the other options are wrong

  • A. T inversion, then hyperacute T waves, then ST elevation: T inversion is a later change, after ST elevation settles.
  • B. Q waves, then ST elevation, then T inversion: Q waves develop after ST elevation, not first.
  • C. ST elevation, then hyperacute T waves, then Q waves: Hyperacute T waves come before ST elevation, not after.

Question 23 · EKG Analysis and Interpretation

What is usually the earliest EKG change of a high serum potassium level?

  1. Prominent U waves
  2. A short PR interval
  3. Tall, peaked T waves
  4. Widened QRS complexes
Show answer and explanation

Correct answer: C. Tall, peaked T waves

Hyperkalemia first shows tall, narrow, symmetrical peaked T waves; P-wave loss and QRS widening follow as potassium rises.

Why the other options are wrong

  • A. Prominent U waves: U waves are linked to low potassium.
  • B. A short PR interval: Hyperkalemia lengthens rather than shortens the PR interval.
  • D. Widened QRS complexes: QRS widening is a later sign.

Question 24 · EKG Analysis and Interpretation

Which pattern defines Mobitz type II second-degree AV block?

  1. PR interval longer than 0.20 second on every beat, with no drops
  2. PR intervals that lengthen until one QRS drops
  3. Constant PR intervals with some P waves not followed by a QRS
  4. More QRS complexes than P waves
Show answer and explanation

Correct answer: C. Constant PR intervals with some P waves not followed by a QRS

In Mobitz type II the PR interval stays constant in conducted beats, but some P waves are suddenly not conducted and their QRS complexes are dropped.

Why the other options are wrong

  • A. PR interval longer than 0.20 second on every beat, with no drops: A long but constant PR with every P conducted is first-degree block.
  • B. PR intervals that lengthen until one QRS drops: Progressive PR lengthening before a dropped beat is Mobitz type I.
  • D. More QRS complexes than P waves: More QRS complexes than P waves is not an AV block pattern; in AV block P waves outnumber QRS complexes.

Sources

Question 25 · EKG Analysis and Interpretation

If the SA node stops firing and the AV node takes over as the pacemaker, about what rate would the technician expect to count?

  1. 60 to 100 beats per minute
  2. 20 to 40 beats per minute
  3. 40 to 60 beats per minute
  4. 100 to 150 beats per minute
Show answer and explanation

Correct answer: C. 40 to 60 beats per minute

Both OpenStax and Open RN give the AV node an inherent backup rate of 40 to 60 beats per minute, slower than the SA node.

Why the other options are wrong

  • A. 60 to 100 beats per minute: 60 to 100 per minute is the normal adult resting rate set by the SA node.
  • B. 20 to 40 beats per minute: Rates this slow belong to pacemaker sites farther down the ventricular pathway.
  • D. 100 to 150 beats per minute: An inherent AV nodal rate is slower than the sinus rate, not faster.

More free EKG practice tests

How this free EKG practice test is built

The CET exam has 120 questions in 2 hours; 100 are scored. This test uses the same domain split, scaled to 25 questions. The questions were written for Medlo; they are not actual exam questions and do not come from NHA. Questions held back for the app’s mock exams and diagnostic are never published here. How we write and review questions.

DomainScored on the examShareIn this test
Safety, Compliance, and Coordinated Patient Care3232%8
EKG Acquisition4444%11
EKG Analysis and Interpretation2424%6

New to the exam? Read the EKG study guide for what to study first, or the EKG exam guide for the format and scoring.

Practice by topic

Free questions for each of the 3 topics, with answers, explanations and sources.

Safety, Compliance, and Coordinated Patient Care · 32 of 100 scored questions

EKG Acquisition · 44 of 100 scored questions

EKG Analysis and Interpretation · 24 of 100 scored questions

Study for the NHA EKG (CET) exam

EKG practice test FAQ

Is this EKG practice test free?
Yes. The questions on this page and on every topic page are free, with no sign-up. Medlo is free to download with a free 20-question EKG diagnostic; some practice is free in the app, and a subscription or Lifetime access unlocks the full question bank, every mock exam and the flashcards.
Are these questions from the CET exam?
No. They were written for Medlo and follow NHA’s published EKG test plan. They are not actual exam questions and do not come from NHA.
How many questions are on the CET exam?
120 questions in 2 hours; 100 are scored.
What else is in the app for the CET exam?
662 practice questions, 4 full mock exams, 636 flashcards, 49 lessons, 15 cheat sheets and a 460-term glossary. One app for CCMA, Phlebotomy (CPT), EKG (CET), RBT and TEAS: one subscription unlocks every exam.
Does it work offline?
Yes. Everything works offline except buying, restoring and sending email.

Other exams in the app

One subscription unlocks every exam in Medlo.

Medlo is an independent app. It is not affiliated with, endorsed by, or sponsored by the National Healthcareer Association (NHA). NHA and Certified EKG Technician (CET) are trademarks of the National Healthcareer Association, used here only to name the exam.

Exams in the app

One app for CCMA, Phlebotomy (CPT), EKG (CET), RBT and TEAS. Each exam has its own question bank, mock exams and free diagnostic; one subscription unlocks all five.

Get the app on the App Store