Medlo
Get the app

EKG Analysis and Interpretation practice questions for the CET exam

EKG Analysis and Interpretation is 24 of the 100 scored questions (24%) on the CET exam. Try 10 free questions below: tap an answer to check it, then read why the other options are wrong and the sources.

10 EKG Analysis and Interpretation questions with answers

10 questions. Tap an answer to check it, or open the explanation under each one.

Question 1

On the treadmill, a patient with an ICD suddenly jerks and says he felt a strong jolt in his chest; he is awake and talking, and the monitor now shows his usual rhythm. What should the technician do?

  1. Keep the belt running, since he looks fine
  2. Ask him to walk faster to see if it recurs
  3. Stop the test, stay with him, and get the provider now
  4. Tell him the shock means the device is broken
Show answer and explanation

Correct answer: C. Stop the test, stay with him, and get the provider now

An ICD shocks when it detects a dangerous ventricular rhythm, so a shock during exercise means a life-threatening arrhythmia may have occurred; the technician stops the test, stays with the patient and gets the supervising provider at once.

Why the other options are wrong

  • A. Keep the belt running, since he looks fine: A shock signals a possible dangerous rhythm, so exercise should not simply continue.
  • B. Ask him to walk faster to see if it recurs: Pushing the workload could provoke the rhythm again.
  • D. Tell him the shock means the device is broken: A shock usually means the device treated a rhythm; judging the device is the provider's role.

Question 2

After the SA node fires, which wave on the EKG shows the atria depolarizing?

  1. QRS complex
  2. T wave
  3. P wave
  4. U wave
Show answer and explanation

Correct answer: C. P wave

The small P wave records atrial depolarization; the QRS records ventricular depolarization and the T wave ventricular repolarization.

Why the other options are wrong

  • A. QRS complex: The QRS complex shows ventricular depolarization.
  • B. T wave: The T wave shows ventricular repolarization.
  • D. U wave: The U wave is not the sign of atrial depolarization.

Question 3

The strip shown begins and ends with a normal beat. According to its reference annotation, what rhythm is the run of wide complexes between about 0.7 and 5.4 seconds?

  1. Ventricular flutter
  2. Ventricular bigeminy
  3. Atrial fibrillation with aberrancy
  4. Ventricular tachycardia
Show answer and explanation

Correct answer: D. Ventricular tachycardia

The MIT-BIH annotation marks the segment from 0.73 to 5.42 seconds as ventricular tachycardia (12 ventricular beats, about 159 per minute), with normal sinus rhythm on either side.

Why the other options are wrong

  • A. Ventricular flutter: The database labels this run ventricular tachycardia, not ventricular flutter.
  • B. Ventricular bigeminy: Bigeminy alternates single PVCs with normal beats; this is a run of 12 ventricular beats.
  • C. Atrial fibrillation with aberrancy: The annotated run is ventricular, not atrial fibrillation.

Question 4

During a code, the technician says, "Dr. Patel, the monitor now shows ventricular fibrillation." Which feature makes this a proper call-out?

  1. It is written in the chart
  2. It is whispered to avoid alarming others
  3. It is sent as a text message
  4. It names the person it is for
Show answer and explanation

Correct answer: D. It names the person it is for

A call-out shares critical information with the whole team at once and addresses it to one named person, so someone clearly owns the next step.

Why the other options are wrong

  • A. It is written in the chart: A call-out is spoken aloud during the event.
  • B. It is whispered to avoid alarming others: A call-out is meant to be heard by the team.
  • C. It is sent as a text message: Texts can go unread; a call-out is spoken in the room.

Sources

Question 5

A manual defibrillator has advised a shock and is charging. What should the team member doing compressions do while it charges?

  1. Keep compressing until told to clear
  2. Stop and stand clear until it is charged
  3. Give two rescue breaths during the charge
  4. Check for a pulse during the charge
Show answer and explanation

Correct answer: A. Keep compressing until told to clear

Compressions continue while the device charges; everyone clears the patient only when the shock is about to be delivered, keeping pauses short.

Why the other options are wrong

  • B. Stop and stand clear until it is charged: Stopping during the charge adds an unnecessary pause in compressions.
  • C. Give two rescue breaths during the charge: Breaths are not given in place of compressions during charging.
  • D. Check for a pulse during the charge: A pulse check during charging interrupts compressions.

Question 6

What is usually the earliest EKG sign of an acute infarction, seen only for minutes before the ST segments rise?

  1. Deep Q waves
  2. Inverted P waves
  3. A short PR interval
  4. Hyperacute T waves
Show answer and explanation

Correct answer: D. Hyperacute T waves

Increased, broad, symmetrical (hyperacute) T waves over the affected area are the earliest sign; they last about 5-30 minutes after onset and are followed by ST changes.

Why the other options are wrong

  • A. Deep Q waves: Q waves take hours to appear.
  • B. Inverted P waves: Inverted P waves are not an infarction sign.
  • C. A short PR interval: A short PR interval is not an early infarction sign.

Question 7

An AED has been attached to a patient in cardiac arrest and announces that it is analyzing the rhythm. What should the technician make sure of?

  1. That the pads are lifted to check the skin
  2. That a 12-lead is recorded at the same time
  3. That compressions continue at full speed
  4. That no one touches or moves the patient
Show answer and explanation

Correct answer: D. That no one touches or moves the patient

During rhythm analysis no one should touch or move the patient, so the device reads the heart rhythm without motion interference.

Why the other options are wrong

  • A. That the pads are lifted to check the skin: Lifting the pads interrupts the analysis.
  • B. That a 12-lead is recorded at the same time: A 12-lead is not run during AED analysis.
  • C. That compressions continue at full speed: Compressions pause briefly for analysis because motion disturbs it.

Question 8

A student asks why there is no separate wave for atrial repolarization on a normal EKG. What is the best explanation?

  1. It occurs only during exercise, not at rest
  2. The atria never repolarize between beats
  3. It happens during the QRS complex, which masks it
  4. It is shown by the T wave after each QRS
Show answer and explanation

Correct answer: C. It happens during the QRS complex, which masks it

Atrial repolarization takes place while the much larger QRS complex is being recorded, so it is hidden on a standard tracing.

Why the other options are wrong

  • A. It occurs only during exercise, not at rest: Atrial repolarization occurs with every beat at any rate.
  • B. The atria never repolarize between beats: All cardiac cells repolarize before they can fire again.
  • D. It is shown by the T wave after each QRS: The T wave represents ventricular, not atrial, repolarization.

Question 9

On one strip the technician finds several PVCs. Some point upward and others point downward, and their shapes clearly differ. How should the PVCs be described?

  1. Unifocal
  2. Fusion
  3. Bigeminal
  4. Multifocal
Show answer and explanation

Correct answer: D. Multifocal

PVCs that look different from one another arise from different sites in the ventricles and are called multifocal; PVCs that all look alike are unifocal.

Why the other options are wrong

  • A. Unifocal: Unifocal PVCs share one shape because they start from one site.
  • B. Fusion: A fusion beat is a single blend of a sinus and a ventricular beat.
  • C. Bigeminal: Bigeminal describes a PVC on every other beat, not PVCs of differing shapes.

Sources

Question 10

A telemetry patient has an 8-second run of ventricular tachycardia that stops on its own; she now feels fine. What should the technician do?

  1. Ignore it because the rhythm has stopped
  2. Delete the event to reduce alarm load
  3. Tell the patient it was harmless
  4. Save the strip and report the run now
Show answer and explanation

Correct answer: D. Save the strip and report the run now

Even a nonsustained VT run is reported promptly per protocol with the saved strip, so the provider can judge it; the technician does not decide that it was harmless.

Why the other options are wrong

  • A. Ignore it because the rhythm has stopped: A VT run needs reporting even after it ends.
  • B. Delete the event to reduce alarm load: Deleting a real event removes information the provider needs.
  • C. Tell the patient it was harmless: Calling it harmless is an interpretation that belongs to the provider.

EKG Analysis and Interpretation terms and cheat sheets

More EKG practice

Take the free 25-question EKG practice test or the free 100-question full-length test, or see what to study first in the EKG study guide.

All EKG practice topicsCET test plan

Medlo is an independent app. It is not affiliated with, endorsed by, or sponsored by the National Healthcareer Association (NHA). NHA and Certified EKG Technician (CET) are trademarks of the National Healthcareer Association, used here only to name the exam.

Exams in the app

One app for CCMA, Phlebotomy (CPT), EKG (CET), RBT and TEAS. Each exam has its own question bank, mock exams and free diagnostic; one subscription unlocks all five.

Get the app on the App Store