23 rhythm strips, one per rhythm label, re-drawn on a standard EKG grid from real recordings in PhysioNet’s open databases. Pick the label for each strip, then open the database’s own annotation and the strip’s measured rate.
Each answer is the database’s own rhythm annotation, shown as published; the numbers come from the database’s beat annotations or, for PTB-XL records, from PTB-XL+ machine measurements. The app has 152 strips in a rhythm drill, plus 662 EKG practice questions.
Name the rhythm: 23 EKG strips
23 strips. Tap a label to check it, or open the answer under each one.
Strip 1 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 100. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
7 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 73 bpm.
Strip 2 of 23
10-second excerpt, PTB-XL, a large publicly available electrocardiography dataset, record 00002. ECG waveform from PTB-XL (Wagner et al., PhysioNet, https://physionet.org/content/ptb-xl/1.0.3/), licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Changes: a 10-second excerpt of selected leads (100 Hz files) is re-drawn as a vector trace on a standard ECG grid, with the window median subtracted.
Which rhythm label did the database give this strip?
ASinus bradycardia
BSecond-degree AV block (type not specified by the database)
Machine measurements (PTB-XL+, GE 12SL, not cardiologist-measured): ventricular rate 47 bpm, PR 152 ms, QRS 88 ms, QT 412 ms, QTc 364 ms. Interval measurements from PTB-XL+ (Strodthoff et al., PhysioNet, https://physionet.org/content/ptb-xl-plus/1.0.1/), 12SL feature set, licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Values copied unchanged.
Strip 3 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 221. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
6 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 65 bpm.
Strip 4 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 202. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
13 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 127 bpm.
Strip 5 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 205. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
ASinus rhythm; Third-degree AV block
BNormal sinus rhythm -> Ventricular tachycardia -> Normal sinus rhythm
CPre-excitation (WPW)
DSinus rhythm; First-degree AV block
Show the database label
Database label: B. Normal sinus rhythm -> Ventricular tachycardia -> Normal sinus rhythm (beats annotated: Premature ventricular contraction x12)
14 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 155 bpm.
Strip 6 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 207. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
6-second excerpt, MIT-BIH Arrhythmia Database, record 231. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
AVentricular trigeminy
BSecond-degree AV block (type not specified by the database)
CSinus rhythm; First-degree AV block
DAtrial fibrillation
Show the database label
Database label: B. Second-degree AV block (type not specified by the database)
4 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 35 bpm.
Strip 8 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 107. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
AAtrial fibrillation
BPaced rhythm
CSupraventricular tachyarrhythmia
DPre-excitation (WPW)
Show the database label
Database label: B. Paced rhythm (beats annotated: Paced beat x7)
7 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 70 bpm.
Strip 9 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 119. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
6 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 69 bpm.
Strip 10 of 23
10-second excerpt, PTB-XL, a large publicly available electrocardiography dataset, record 00108. ECG waveform from PTB-XL (Wagner et al., PhysioNet, https://physionet.org/content/ptb-xl/1.0.3/), licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Changes: a 10-second excerpt of selected leads (100 Hz files) is re-drawn as a vector trace on a standard ECG grid, with the window median subtracted.
Which rhythm label did the database give this strip?
ASecond-degree AV block (type not specified by the database)
Machine measurements (PTB-XL+, GE 12SL, not cardiologist-measured): ventricular rate 121 bpm, PR 148 ms, QRS 70 ms, QT 318 ms, QTc 451 ms. Interval measurements from PTB-XL+ (Strodthoff et al., PhysioNet, https://physionet.org/content/ptb-xl-plus/1.0.1/), 12SL feature set, licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Values copied unchanged.
Strip 11 of 23
10-second excerpt, PTB-XL, a large publicly available electrocardiography dataset, record 00098. ECG waveform from PTB-XL (Wagner et al., PhysioNet, https://physionet.org/content/ptb-xl/1.0.3/), licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Changes: a 10-second excerpt of selected leads (100 Hz files) is re-drawn as a vector trace on a standard ECG grid, with the window median subtracted.
Which rhythm label did the database give this strip?
Machine measurements (PTB-XL+, GE 12SL, not cardiologist-measured): ventricular rate 64 bpm, PR 214 ms, QRS 82 ms, QT 370 ms, QTc 381 ms. Interval measurements from PTB-XL+ (Strodthoff et al., PhysioNet, https://physionet.org/content/ptb-xl-plus/1.0.1/), 12SL feature set, licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Values copied unchanged.
Strip 12 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 222. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
AIdioventricular rhythm
BNormal sinus rhythm -> Ventricular tachycardia -> Normal sinus rhythm
8 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 85 bpm.
Strip 13 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 209. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
15 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 149 bpm.
Strip 14 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 124. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
6 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 62 bpm.
Strip 15 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 230. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
9 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 82 bpm.
Strip 16 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 119. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
6 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 69 bpm.
Strip 17 of 23
6-second excerpt, MIT-BIH Arrhythmia Database, record 124. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
6 QRS complexes annotated in the excerpt; mean rate from the annotated R-R intervals: 59 bpm.
Strip 18 of 23
6-second excerpt, MIT-BIH Malignant Ventricular Ectopy Database, record 430. Contains information from the MIT-BIH Malignant Ventricular Ectopy Database (https://physionet.org/content/vfdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
6-second excerpt, MIT-BIH Malignant Ventricular Ectopy Database, record 422. Contains information from the MIT-BIH Malignant Ventricular Ectopy Database (https://physionet.org/content/vfdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
6-second excerpt, MIT-BIH Malignant Ventricular Ectopy Database, record 607. Contains information from the MIT-BIH Malignant Ventricular Ectopy Database (https://physionet.org/content/vfdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Which rhythm label did the database give this strip?
10-second excerpt, PTB-XL, a large publicly available electrocardiography dataset, record 00209. ECG waveform from PTB-XL (Wagner et al., PhysioNet, https://physionet.org/content/ptb-xl/1.0.3/), licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Changes: a 10-second excerpt of selected leads (100 Hz files) is re-drawn as a vector trace on a standard ECG grid, with the window median subtracted.
Which rhythm label did the database give this strip?
ASinus rhythm; First-degree AV block
BAsystole
CNormal sinus rhythm -> Ventricular tachycardia -> Normal sinus rhythm
DAtrial flutter
Show the database label
Database label: A. Sinus rhythm; First-degree AV block
Machine measurements (PTB-XL+, GE 12SL, not cardiologist-measured): ventricular rate 67 bpm, PR 310 ms, QRS 94 ms, QT 380 ms, QTc 401 ms. Interval measurements from PTB-XL+ (Strodthoff et al., PhysioNet, https://physionet.org/content/ptb-xl-plus/1.0.1/), 12SL feature set, licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Values copied unchanged.
Strip 22 of 23
10-second excerpt, PTB-XL, a large publicly available electrocardiography dataset, record 00959. ECG waveform from PTB-XL (Wagner et al., PhysioNet, https://physionet.org/content/ptb-xl/1.0.3/), licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Changes: a 10-second excerpt of selected leads (100 Hz files) is re-drawn as a vector trace on a standard ECG grid, with the window median subtracted.
Which rhythm label did the database give this strip?
AVentricular bigeminy
BVentricular flutter
CSinus rhythm; Third-degree AV block
DAtrial flutter
Show the database label
Database label: C. Sinus rhythm; Third-degree AV block
Machine measurements (PTB-XL+, GE 12SL, not cardiologist-measured): ventricular rate 40 bpm, QRS 138 ms, QT 614 ms, QTc 500 ms. Interval measurements from PTB-XL+ (Strodthoff et al., PhysioNet, https://physionet.org/content/ptb-xl-plus/1.0.1/), 12SL feature set, licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Values copied unchanged.
Strip 23 of 23
10-second excerpt, PTB-XL, a large publicly available electrocardiography dataset, record 00320. ECG waveform from PTB-XL (Wagner et al., PhysioNet, https://physionet.org/content/ptb-xl/1.0.3/), licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Changes: a 10-second excerpt of selected leads (100 Hz files) is re-drawn as a vector trace on a standard ECG grid, with the window median subtracted.
Which rhythm label did the database give this strip?
Machine measurements (PTB-XL+, GE 12SL, not cardiologist-measured): ventricular rate 55 bpm, PR 210 ms, QRS 102 ms, QT 508 ms, QTc 485 ms. Interval measurements from PTB-XL+ (Strodthoff et al., PhysioNet, https://physionet.org/content/ptb-xl-plus/1.0.1/), 12SL feature set, licensed under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Values copied unchanged.
4 more labeled strips
Sinus rhythm with annotated extra or abnormal beats, labeled as the database annotates them.
Normal sinus rhythm (beats annotated: Atrial premature beat x1) 6-second excerpt, MIT-BIH Arrhythmia Database, record 100. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).Normal sinus rhythm (beats annotated: Premature ventricular contraction x1) 6-second excerpt, MIT-BIH Arrhythmia Database, record 116. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).Normal sinus rhythm (beats annotated: Premature ventricular contraction x3) 6-second excerpt, MIT-BIH Arrhythmia Database, record 200. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).Normal sinus rhythm (beats annotated: Left bundle branch block beat x9) 6-second excerpt, MIT-BIH Arrhythmia Database, record 109. Contains information from the MIT-BIH Arrhythmia Database (https://physionet.org/content/mitdb/1.0.0/) which is made available under the ODC Attribution License (https://opendatacommons.org/licenses/by/1-0/).
Strips: vector re-drawings of PhysioNet records; changes: short excerpts re-drawn on a standard grid. Database notices, citations and licences: Sources and credits.
Medlo is an independent app. It is not affiliated with, endorsed by, or sponsored by the National Healthcareer Association (NHA). NHA and Certified EKG Technician (CET) are trademarks of the National Healthcareer Association, used here only to name the exam.
Exams in the app
One app for CCMA, Phlebotomy (CPT), EKG (CET), RBT and TEAS. Each exam has its own question bank, mock exams and free diagnostic; one subscription unlocks all five.