25 questions, none of them in practice test 1 or the other numbered test, split across the 3 domains by exam weight. They are also part of the full-length test. Tap an answer to check it and see your score at the end. No sign-up.
25 NHA EKG (CET) practice questions with answer explanations
25 questions. Tap an answer to check it, or open the explanation under each one.
Question 1 · Safety, Compliance, and Coordinated Patient Care
A patient walks into a cardiology office and asks the EKG technician to run a quick EKG because her heart felt fluttery yesterday. There is no provider order. What should the technician do?
ATell her the fluttering is nothing to worry about
BLet the provider know so she can be evaluated
CRecord the EKG and give her the printout
DSend her home and tell her to call next week
Show answer and explanation
Correct answer: B. Let the provider know so she can be evaluated
The CET test plan has the technician review the provider's order before applying electrodes (task 2F); a symptom report is passed to the provider, who decides on evaluation and testing.
Why the other options are wrong
A. Tell her the fluttering is nothing to worry about: Reassuring her is a clinical judgment the technician cannot make.
C. Record the EKG and give her the printout: An EKG is done on a provider's order, and the result goes to the provider.
D. Send her home and tell her to call next week: Sending her away ignores a symptom that the provider should hear about.
Question 2 · Safety, Compliance, and Coordinated Patient Care
At 3 a.m. an alert, oriented telemetry patient declines a repeat 12-lead. A coworker says the refusal shows she is confused and the EKG should be done anyway. What should the technician do?
AWait until she falls asleep and record it then
BRespect the refusal, document it and notify her nurse
CPhone her daughter for permission to go ahead
DRecord it, since refusing ordered care shows confusion
Show answer and explanation
Correct answer: B. Respect the refusal, document it and notify her nurse
Patients have the right to refuse, and a refusal is not by itself evidence of diminished capacity; capacity is assessed when it seems questionable, not solely because the patient refuses. The technician documents the refusal and reports it so the team can follow up.
Why the other options are wrong
A. Wait until she falls asleep and record it then: Recording on a sleeping patient who refused is testing without consent.
C. Phone her daughter for permission to go ahead: A capable adult decides for herself; a relative cannot override her.
D. Record it, since refusing ordered care shows confusion: Refusal alone does not show a lack of capacity.
Question 4 · Safety, Compliance, and Coordinated Patient Care
An alert patient asks the technician to let her husband stay in the room and hear the explanation of her stress test. What should the technician do?
AAsk the husband to wait outside, as HIPAA requires
BHave the husband sign a HIPAA release form first
CAsk the provider for written permission first
DLet him stay, since the patient has agreed to it
Show answer and explanation
Correct answer: D. Let him stay, since the patient has agreed to it
Under 45 CFR 164.510(b), when a patient with capacity is present and agrees, information relevant to a family member's involvement in her care may be shared with that person.
Why the other options are wrong
A. Ask the husband to wait outside, as HIPAA requires: HIPAA does not require excluding family the patient wants present.
B. Have the husband sign a HIPAA release form first: No signed release is needed when the patient is present and agrees.
C. Ask the provider for written permission first: The patient's own agreement is what matters; no written provider permission is required.
Question 5 · Safety, Compliance, and Coordinated Patient Care
A health insurer asks the cardiology clinic for documents to process its claim for one resting EKG. Under HIPAA's minimum necessary standard, what should the clinic send?
AThe patient's entire cardiology chart
BNothing, unless she gives written permission
CThat EKG plus all of her earlier stress tests
DJust the documentation this claim requires
Show answer and explanation
Correct answer: D. Just the documentation this claim requires
Disclosures for payment need no patient authorization (45 CFR 164.506(c)), but they must be limited to the minimum necessary to accomplish the purpose (45 CFR 164.502(b)).
Why the other options are wrong
A. The patient's entire cardiology chart: The full chart is far more than one claim requires.
B. Nothing, unless she gives written permission: Payment disclosures do not require an authorization.
C. That EKG plus all of her earlier stress tests: Earlier tests are not needed for this one claim.
Question 7 · Safety, Compliance, and Coordinated Patient Care
Skin prep for a treadmill test begins on a chest that is wet with perspiration. Which substance does CDC leave out of the list of materials assumed able to transmit infection under Standard Precautions?
ASweat
BSaliva
CBlood
DRespiratory secretions
Show answer and explanation
Correct answer: A. Sweat
CDC/HICPAC builds Standard Precautions on the assumption that blood, body fluids, secretions, excretions, nonintact skin and mucous membranes may carry transmissible agents. Sweat is the single body fluid named as an exception.
Why the other options are wrong
B. Saliva: Saliva is a secretion and stays on the list.
C. Blood: Blood is the core material Standard Precautions protect against.
D. Respiratory secretions: Respiratory secretions are covered and also drive respiratory hygiene.
A technician is setting up an exercise stress lab. Which item must be readily available in the room?
AA tabletop autoclave
BA centrifuge
CA defibrillator on an emergency cart
DA Holter recorder with spare batteries
Show answer and explanation
Correct answer: C. A defibrillator on an emergency cart
Exercise testing labs must be equipped for emergencies: essential equipment includes the ergometer, an electrocardiograph, a BP monitor, oxygen, an emergency telephone and an emergency cart equipped with a defibrillator.
Why the other options are wrong
A. A tabletop autoclave: An autoclave sterilizes instruments; it is not stress-lab equipment.
B. A centrifuge: A centrifuge is laboratory equipment.
D. A Holter recorder with spare batteries: A Holter recorder is for ambulatory monitoring, not stress-lab safety.
In the emergency department, a cart comes with a pre-spaced chest electrode strip. On a very small adult, the strip's V4 to V6 pads land well beyond the measured landmarks. What should the technician do?
AUse the strip and note the patient's small size on the tracing
BPlace individual electrodes on measured landmarks
CShift the whole strip up one rib space
DUse the strip, since it is designed for speed
Show answer and explanation
Correct answer: B. Place individual electrodes on measured landmarks
Pre-positioned strips that ignore chest size cannot be treated as diagnostic quality; chest electrodes must follow standard placement.
Why the other options are wrong
A. Use the strip and note the patient's small size on the tracing: A note does not correct the misplaced electrodes.
C. Shift the whole strip up one rib space: Moving the strip still leaves pads off their landmarks.
D. Use the strip, since it is designed for speed: Speed does not justify off-landmark sites.
10 down. Medlo has 637 more EKG (CET) questions, each answer explained.Get Medlo
Question 11 · EKG Acquisition
An order reads "14-day ambulatory ECG," but the clinic's wired Holter recorders are set up for 48-hour studies. What should the technician do before hooking up the patient?
AReplace it with a resting 12-lead EKG and a rhythm strip
BCheck with the ordering provider which device and duration to use
CFit the 48-hour Holter, since any ambulatory recording will do
DFit the 48-hour Holter and ask the patient to come back twice more
Show answer and explanation
Correct answer: B. Check with the ordering provider which device and duration to use
Devices differ in how long they record (traditional Holter 24 to 48 hours; patch monitors up to about 14 days). The technician reviews the order and clarifies a mismatch with the provider instead of substituting another test.
Why the other options are wrong
A. Replace it with a resting 12-lead EKG and a rhythm strip: A short resting tracing cannot replace two weeks of monitoring.
C. Fit the 48-hour Holter, since any ambulatory recording will do: Substituting a different duration changes the ordered test.
D. Fit the 48-hour Holter and ask the patient to come back twice more: Chaining short studies changes the order without the provider's agreement.
During recovery, a patient slumps in the chair and does not respond when tapped and shouted at. He is not breathing normally. What should the technician do?
AGive him water and recheck in five minutes
BRun a full 12-lead tracing to document the rhythm first
CRaise his legs and wait for him to wake up
DCall for help with the room alarm and start CPR
Show answer and explanation
Correct answer: D. Call for help with the room alarm and start CPR
For an unresponsive patient who is not breathing normally, BLS calls for activating emergency help, starting high-quality chest compressions and using an AED or defibrillator as soon as it is available.
Why the other options are wrong
A. Give him water and recheck in five minutes: Delay in cardiac arrest costs brain function and life.
B. Run a full 12-lead tracing to document the rhythm first: Recording a tracing delays CPR in a cardiac arrest.
C. Raise his legs and wait for him to wake up: An unresponsive person who is not breathing normally needs CPR.
One lead on a finished 12-lead shows heavy artifact. A coworker suggests cropping that lead out of the stored file before sending so the tracing looks clean. What should the technician do?
ASend it with a note that one lead was removed
BDelete the stored file and send nothing
CFix the cause and record a new tracing to send
DCrop the lead and send the edited file
Show answer and explanation
Correct answer: C. Fix the cause and record a new tracing to send
HIPAA requires policies that protect electronic health information from improper alteration, and a tracing is checked for quality before it goes to the provider. The technician corrects the artifact and repeats the tracing instead of editing the record.
Why the other options are wrong
A. Send it with a note that one lead was removed: A tracing with a lead removed is still an altered, incomplete record.
B. Delete the stored file and send nothing: The provider still needs a usable tracing.
D. Crop the lead and send the edited file: Editing a stored tracing alters the record and hides data.
During a pre-op EKG the technician realises V1 and V2 went in the 2nd intercostal space, and the machine statement now mentions a possible anterior infarct. What is the best next step?
ATell the patient the tracing shows a heart attack
BSend the tracing and let the provider decide
CRe-place V1 and V2 in the 4th intercostal space and record a new tracing
DMove all six chest electrodes up one space to match
Show answer and explanation
Correct answer: C. Re-place V1 and V2 in the 4th intercostal space and record a new tracing
High V1 and V2 can produce false infarct patterns that resolve once the electrodes are placed correctly, so the technician corrects the sites and repeats the tracing, reporting per protocol.
Why the other options are wrong
A. Tell the patient the tracing shows a heart attack: Technicians do not diagnose, and this finding may be an artifact of placement.
B. Send the tracing and let the provider decide: Sending a known misplaced tracing risks a false diagnosis.
D. Move all six chest electrodes up one space to match: Moving the rest makes the whole chest set wrong.
The central monitor shows a flat line with an asystole alarm. At the bedside the patient is sitting up and talking, and an electrode is lying on the sheet. What should the technician do next?
AReattach a fresh electrode and recheck
BChart the event as asystole
CTurn the asystole alarm off for this shift
DStart chest compressions right away
Show answer and explanation
Correct answer: A. Reattach a fresh electrode and recheck
A detached electrode can produce a false asystole display. The patient is responsive, so the fix is a fresh electrode, a check that the waveform has returned, and a report per protocol.
Why the other options are wrong
B. Chart the event as asystole: The flat line is a lead problem, and the technician does not chart a diagnosis.
C. Turn the asystole alarm off for this shift: Disabling alarms can hide a real event.
D. Start chest compressions right away: CPR is for an unresponsive patient who is not breathing normally, not a talking patient.
A regular rhythm strip was recorded at 50 mm/s. The R waves are 30 small boxes apart, and a coworker reports a rate of 50/min using 1,500 / 30. What is the actual heart rate?
A50/min
B75/min
C100/min
D150/min
Show answer and explanation
Correct answer: C. 100/min
At 50 mm/s each small box is 0.02 second, so the R-R interval is 30 x 0.02 = 0.60 second, and 60 / 0.60 = 100/min. The 1,500 rule assumes 25 mm/s, which is why the paper speed is checked first.
Why the other options are wrong
A. 50/min: 50/min applies the 25 mm/s rule to a 50 mm/s strip, halving the true rate.
B. 75/min: 75/min does not follow from 30 boxes at either speed.
D. 150/min: 150/min would need an R-R interval of 0.40 second.
Midway through a 12-lead, the patient lifts her right hand to scratch her nose. For that moment the limb leads show a few sudden, sharp, irregular deflections that could pass for premature beats. What caused them?
ASlow baseline drift from her breathing
BGel bridging between chest electrodes
C60-cycle interference from the cart
DLimb movement during the recording
Show answer and explanation
Correct answer: D. Limb movement during the recording
Patients who move their limbs during the test cause sudden irregularities in the baseline that may resemble premature contractions; the technician asks the patient to keep still and repeats the tracing.
Why the other options are wrong
A. Slow baseline drift from her breathing: Breathing causes a slow swing of the baseline, not sharp deflections.
B. Gel bridging between chest electrodes: Gel bridging makes the chest leads look alike; it does not cause sudden limb-lead deflections.
C. 60-cycle interference from the cart: 60-cycle interference is continuous, even fuzz, not brief sharp marks tied to a movement.
A patient in ventricular tachycardia says he only feels his heart racing. Why is this rhythm still treated as life-threatening?
AIt always stops on its own within seconds
BIt causes damage only to the atria
CIt affects only patients with pacemakers
DIt can quickly lead to collapse
Show answer and explanation
Correct answer: D. It can quickly lead to collapse
VT can cause anything from no symptoms or palpitations to collapse and death, and a fast ventricular rate is tolerated only briefly, so it needs an emergency response even when the patient is talking.
Why the other options are wrong
A. It always stops on its own within seconds: Sustained VT lasts 30 seconds or more and may not stop by itself.
B. It causes damage only to the atria: VT starts in the ventricles and threatens the whole circulation.
C. It affects only patients with pacemakers: VT occurs in many patients, most with structural heart disease, not only those with pacemakers.
Tall, peaked P waves in leads II, III and aVF are associated with which change?
AHypercalcemia
BLeft atrial enlargement
CLeft bundle branch block (LBBB)
DRight atrial enlargement
Show answer and explanation
Correct answer: D. Right atrial enlargement
Right atrial enlargement produces a tall, peaked P wave in II, III and aVF (P pulmonale); left atrial enlargement produces a broad, double-peaked P in lead II.
Why the other options are wrong
A. Hypercalcemia: Hypercalcemia shortens the QT interval.
B. Left atrial enlargement: Left atrial enlargement gives a broad, notched P wave.
C. Left bundle branch block (LBBB): Bundle branch block widens the QRS, not the P wave.
A regular sinus rhythm at 75 shows a P wave before every QRS and a normal PR, but each QRS measures 4 small boxes at 25 mm/s. How should the technician describe the QRS?
ANormal, 0.08 second
BWide, 0.20 second
CNormal, 0.12 second
DWide, 0.16 second
Show answer and explanation
Correct answer: D. Wide, 0.16 second
One small box is 0.04 second, so 4 x 0.04 = 0.16 second; a QRS of 0.12 second or more is wide and is reported for the provider to evaluate, for example for bundle branch block.
Why the other options are wrong
A. Normal, 0.08 second: 4 small boxes is 0.16 second, not 0.08 second.
B. Wide, 0.20 second: 0.20 second would be 5 small boxes.
C. Normal, 0.12 second: 4 small boxes is 0.16 second, and 0.12 second or more is not normal.
The questions were written for Medlo; they are not actual exam questions and do not come from NHA. Every question comes from the app’s practice pool; questions held back for the app’s mock exams and diagnostic are never published here.
Medlo is an independent app. It is not affiliated with, endorsed by, or sponsored by the National Healthcareer Association (NHA). NHA and Certified EKG Technician (CET) are trademarks of the National Healthcareer Association, used here only to name the exam.
Exams in the app
One app for CCMA, Phlebotomy (CPT), EKG (CET), RBT and TEAS. Each exam has its own question bank, mock exams and free diagnostic; one subscription unlocks all five.